Camera interfaces
For all Manta models:
Test conditions
Output: external 2.4 k resistor to GND, Isolated Out Power set to 12 V.
Figure 79: Manta output switching times
Parameter and value
t
d
1 µs t
s
26 µs
t
r
1 µs t
f
21 µs
t
on
= t
d
+ t
r
2 µs t
off
= t
s
+ t
f
47 µs
(t
off
can deviate by 5 µs)
Table 39: Parameters for Manta
Note
Higher external values increase the times in the table above.
I
F
0
I
C
100%
90%
10%
t
t
0
delay time
rise time
turn-on time
storage time
fall time
turn-o time
Optocoup
ler input (internal)
Optocoupler output (extern
al)
t
o
(= t
s
+ t
f
)
t
d
t
r
t
on
(= t
d
+ t
r
)
t
s
t
f
t
d
t
on
t
r
t
s
t
f
t
o